CDD-562L/564 Demodulator with IP Module
Revision 2
Updating Firmware
MN/CDD564L.IOM
5–8
5.3.3
Bulk Firmware FTP Upload Procedure
Step
Task
1
Verify that:
•
The firmware update has been downloaded to the user PC and is available in the
temporary folder, and
•
The user PC is connected to the CDD-56X
10/100 Ethernet
port either via a hub or a
switch or with a direct Ethernet cable connection, and that the CDD-56X
Console
port
(do
NOT
use the
Remote Control
port) is connected to a serial port on the user PC
using an adapter cable.
2
Confirm that there is proper connection and communication between the user PC and the
CDD-56X.
First
, determine the IP Address as follows:
•
Using the front panel
– use the
SELECT: CONFIG
Æ
Remote
Æ
Remote
Æ
Ethernet
menu.
•
Using serial remote control
– use the
<0/IPA?
query.
Then
, use Command-line to “ping” the modem:
•
From Windows, click
[Start]
on the Windows toolbar, and then select the
Run...
option
(as an alternative, use the ‘
Command-line Prompt’
or ‘
Command Prompt’
icon in
the
Start
menu):
o
Using Win95 or Win98
– Type “
command
”.
o
Using WinNT, Win2K or WinXP
– Type “
cmd
”.
Type “
ping xxx.xxx.xxx.xxx
” at the Command-line prompt (where "
xxx.xxx.xxx.xxx
" is the
CDD-56X IP Address). The results should confirm whether or not the modem is connected and
communicating.
3
Use Command-line to initiate an FTP session with the CDD-56X:
A.
Type "
ftp xxx.xxx.xxx.xxx
" (where ‘xxx.xxx.xxx.xxx’ denotes the unit IP Address).
B.
Enter the
Admin User Name
and
Password
to complete login.
C.
Type “
bin
” to set the binary transfer mode.
D.
Type "
prompt"
, and then type "
hash
" to facilitate the file transfers.
4
Upload the files from the temporary folder on the user PC:
Type "
put FW-0000###*.bin
" (where ‘0000###’ is the firmware number, and ’*’ is the
firmware revision letter) to begin the file transfers.
The process sequences through several blocks – this may take several minutes. When the
firmware update image file has been uploaded, it will be written to flash memory.
Summary of Contents for Vipersat CDD-562L
Page 2: ......
Page 4: ...ii This page is intentionally blank ...
Page 24: ...CDD 562L 564 Demodulator with Optional IP Module Revision 2 Preface MN CDD564L IOM xxii Notes ...
Page 40: ...CDD 562L 564 Demodulator with IP Module Revision 2 Introduction MN CDD564L IOM 1 16 Notes ...
Page 206: ...CDD 562L 564 Demodulator with IP Module Revision 2 Appendix A MN CDD564L IOM A 6 Notes ...
Page 216: ...CDD 562L 564 Demodulator with IP Module Revision 2 Appendix C MN CDD564L IOM C 4 Notes ...
Page 254: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...