CDD-562L/564 Demodulator with IP Module
Revision 2
CDD-56X CLI and Telnet Operation
MN/CDD564L.IOM
8–31
Selection
Entry Description
Descrambling
B
Select one of the following:
1 – Off
2 – On-Default
3 – On-IESS-315
Acquisition Range
W
Valid ranges are from 0 to 200 kHz:
•
1 to 32HKz if symbol rate < 625Ksymbol on CDD-564L
•
1 to 32HKz on CDD-564
Eb/No Alarm Point
P
Valid range is from 0.1 to 16.0.
8.2.7.1.2
Alarm Masks Configuration (Per Demod) page
Access the
Alarm Masks Configuration (Per Demod)
page from the
Configuration
page
.
This page contains the following unique selections/fields:
Selection
Entry Description
Rx AGC (Auto Gain Control) Mask
D
Select as [Active] or [Masked].
Eb/No Mask
E
Select as [Active] or [Masked].
LNB Mask
J
Select as [Active] or [Masked], when the presence of an LNB is
detected.