CRS-311 1:1 Redundancy Switch
Revision 7
Serial-based Remote Product Management
MN/CRS311.IOM
6–13
Parameter Type
Command
(Code and
qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes:
i.e., ASCII codes between 48 and 57)
Response to Command
(Target-to-Controller)
Query
(Code and qualifier)
Response to query
(Target-to-Controller)
Restore Holdoff
Time
RSH=
2 bytes, numerical Command or Query.
The restore holdoff time is the delay when auto mode prepares to
return a modem (previously faulted, now good) back online due to a
different Traffic Modem’s failure:
01-99 = # of seconds after offline Traffic Modem lost its fault before
it is put back online..
RSH= (message OK)
RSH? (received OK, but
invalid arguments found)
RSH* (message OK, not
permitted in current mode)
RSH?
RSH=xx
(see description of
arguments)
Switch Alarm
Mask
SAM=
1 byte, numerical
Command or Query.
x indicates the Switch alarm mask:
0 = no faults masked
1 = PSU-A faults masked
2 = PSU-B faults masked
SAM= (message OK)
SAM? (received OK, but
invalid arguments found)
SAM* (message OK, but not
permitted in current mode)
SAM?
SAM=x
(see description of
arguments)
Switch Global
Configuration
SGC=
29 bytes, numerical Command or Query.
Global configuration of the Switch, in the form:
OasssssssssBNNbbrrMSAssssssss, where:
O = Operating Mode – same as OPM (1 bytes)
a = Active Modem – same as ACT for TM (1 byte)
s = 9 spare bytes
B = Bridge/Backup State – same as BBU (1 byte)
NN = always 01 for the 311
bb = Backup Holdoff Time – same as BKH (2 byte)
rr = Restore Holdoff Time – same as RSH (2 byte)
M = Modem Alarm Mask – same as MAM (1 byte)
S = Switch Alarm Mask – same as SAM (1 byte)
A = Audio Alarm Mask – same as AAM (1 bytes)
s = 8 spare bytes
SGC= (message OK)
SGC? (received OK, but
invalid arguments found)
SGC* (message OK, but not
permitted in current mode)
SGC?
SGC=OasssssssssBNNbbrr
MSAssssssss
(see description of
arguments)
Switch ID
SID=
24 bytes, ASCII
Command or Query.
A user-defined Switch ID, which is a fixed length of 24 characters.
Valid characters include:
Space ( ) * + - , . / 0-9 and A-Z.
SID= (message OK)
SID? (received OK, but
invalid arguments found)
SID* (message OK, but not
permitted in current mode)
SID?
SID=xxxxxxxxxxxxxxxxxxxxx
xxx
(see description of
arguments)
Serial Number
N/A
9 bytes, numerical Query only.
Unit returns its 9-digit serial number.
Example: SNO=176512523
N/A SNO?
SNO=xxxxxxxxx
(see description of
arguments)
Software Revision N/A
5 bytes, numerical Query only.
Unit returns the value of internal software revision installed in the
unit, in the form x.x.x
Example: SWR=1.0.1 (indicating Version 1.0.1)
N/A SWR?
SWR=x.x.x
(see description of
arguments)
Summary of Contents for CRS-311
Page 22: ...CRS 311 1 1 Redundancy Switch Revision 7 Preface MN CRS311 IOM xxii Notes...
Page 48: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 2 Notes...
Page 62: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 16 Notes...
Page 128: ...CRS 311 1 1 Redundancy Switch Revision 7 Front Panel Operation MN CRS311 IOM 5 20 Notes...
Page 166: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix A MN CRS311 IOM A 24 Notes...
Page 178: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix B MN CRS311 IOM B 12 Notes...
Page 186: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix C MN CRS311 IOM C 8 Notes...
Page 194: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...