CRS-311 1:1 Redundancy Switch
Revision 7
Cables and Connections
MN/CRS311.IOM
3–5
3.2.4
Data Traffic Connections – CRS-311 to Modems
3.2.4.1 EIA-530 V.35/EIA-232 Data Traffic Connections
Referring
to
Figure
3
‐
2
,
connect
and
secure
the
CA/WR0066
‐
4
25
‐
pin
Control
and
Data
Cable
between
the
CRS
‐
311
and
each
CDM
‐
Qx/QxL
as
follows:
•
From
the
DB
‐
25M
connector
labeled
“P2”
on
the
RMI
or
“P1”
on
the
TMI,
to
•
The
DB
‐
25F
connector
labeled
“EIA
‐
530”
on
the
demodulator.
3.2.4.2 Balanced G.703 Data Traffic Connections
Referring
to
Figure
3
‐
3
,
connect
and
secure
the
CA/WR9038
‐
4
15
‐
pin
Data
Cable
between
the
CRS
‐
311
and
each
CDM
‐
Qx/QxL
as
follows:
•
From
the
DB
‐
15M
connector
labeled
“P1”
on
the
RMI
or
TMI,
to
•
The
DB
‐
15F
connector
labeled
“G.703”
on
the
demodulator.
3.2.4.3 Unbalanced G.703 Data Traffic Connections
Referring
to
Figure
3
‐
4:
•
First,
connect
and
secure
the
CA/WR0813
‐
4
BNC
Tx
Cable
between
the
CRS
‐
311
and
each
CDM
‐
Qx/QxL
as
follows:
o
From
the
BNC
connector
labeled
“J4”
on
the
RMI
or
“J3”
on
the
TMI,
to
o
The
BNC
connector
labeled
“Tx”
on
the
demodulator.
•
Next,
connect
and
secure
the
CA/WR0813
‐
4
BNC
Rx
Cable
between
the
CRS
‐
311
and
each
CDM
‐
Qx/QxL
as
follows:
o
From
the
BNC
connector
labeled
“J3”
on
the
RMI
or
“J5”
on
the
TMI,
to
o
The
BNC
connector
labeled
“Rx”
on
the
demodulator.
3.2.4.4 HSSI Data Traffic Connections
Referring
to
Figure
3
‐
5
,
connect
and
secure
the
CA/WR9189
‐
4
HSSI
Data
Cable
between
the
CRS
‐
311
and
each
CDM
‐
Qx/QxL
as
follows:
•
From
the
HSSI
connector
labeled
“J2”
on
the
RMI
or
“J3”
on
the
TMI,
to
•
The
HSSI
connector
labeled
“HSSI”
on
the
demodulator.
Summary of Contents for CRS-311
Page 22: ...CRS 311 1 1 Redundancy Switch Revision 7 Preface MN CRS311 IOM xxii Notes...
Page 48: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 2 Notes...
Page 62: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 16 Notes...
Page 128: ...CRS 311 1 1 Redundancy Switch Revision 7 Front Panel Operation MN CRS311 IOM 5 20 Notes...
Page 166: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix A MN CRS311 IOM A 24 Notes...
Page 178: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix B MN CRS311 IOM B 12 Notes...
Page 186: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix C MN CRS311 IOM C 8 Notes...