CRS-311 1:1 Redundancy Switch
Revision 7
Cables and Connections
MN/CRS311.IOM
3–18
•
Make
sure
there
is
no
system
contention
from
the
modem
Tx
carrier.
3.3.2
System Control Cable Connections – CRS-311 to Modems
The
CA/WR12136
‐
2
Control
Cable
provides
the
serial
communication
path
between
the
CRS
‐
311
and
the
modems
and
controls
the
modem’s
external
Tx
IF
‐
mute
control
line,
and
is
therefore
always
required.
In
order
to
provide
user
access
to
the
AGC
and
I&Q
outputs
of
the
modem,
the
CA/WR12842
‐
4
(4’
length)
and
CA/WR12842
‐
6
(6’
length)
Control
‘Y’
Cables,
sold
separately,
are
available
for
use
in
place
of
the
CA/WR12136
‐
2
Control
Cable.
See
Appendix
A.
CABLE
DRAWING
S
for
detailed
information
about
these
optional
cable
assemblies.
Referring
to
Figure
3
‐
9
through
Figure
3
‐
21:
Connect
and
secure
the
CA/WR12136
‐
2
Control
Cable
(or
the
CA/WR12842
‐
4
Control
‘Y’
Cables,
if
used)
between
the
CRS
‐
311
and
each
SLM
‐
5650/5650A
as
follows:
•
From
the
HD
‐
15F
connector
labeled
“J1”
on
the
RMI
or
TMI,
to
•
The
HD
‐
15F
connector
labeled
“J9
Auxiliary”
on
the
SLM
‐
5650/5650A.
3.3.3
Serial Data Traffic Cable Connections – CRS-311 to Modems
3.3.3.1 EIA-530 Data Traffic Connections
Referring
to
Figure
3
‐
9:
Connect
and
secure
the
CA/WR0066
‐
4
Data
Cable
between
the
CRS
‐
311
and
each
SLM
‐
5650/5650A
as
follows:
•
From
the
DB
‐
25M
connector
labeled
“P2”
on
the
RMI
or
“P1”
on
the
TMI,
to
•
The
DB
‐
25F
connector
labeled
“J6
EIA530”
on
the
SLM
‐
5650/5650A.
3.3.3.2 Balanced G.703 Data Traffic Connections
Referring
to
Figure
3
‐
10
Connect
and
secure
the
CA/WR9038
‐
4
Balanced
G.703
Data
Cable
between
the
CRS
‐
311
and
each
SLM
‐
5650/5650A
(via
the
optional
G.703
Interface
Module)
as
follows:
Summary of Contents for CRS-311
Page 22: ...CRS 311 1 1 Redundancy Switch Revision 7 Preface MN CRS311 IOM xxii Notes...
Page 48: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 2 Notes...
Page 62: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 16 Notes...
Page 128: ...CRS 311 1 1 Redundancy Switch Revision 7 Front Panel Operation MN CRS311 IOM 5 20 Notes...
Page 166: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix A MN CRS311 IOM A 24 Notes...
Page 178: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix B MN CRS311 IOM B 12 Notes...
Page 186: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix C MN CRS311 IOM C 8 Notes...
Page 194: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...