CRS-311 1:1 Redundancy Switch
Revision 7
Modem, RMI/TMI, and Switch Configuration MN/CRS311.IOM
4–10
Table 4-2. CRS-515 TMI Factory-configured Jumper Settings
Modem Jumper ‘JMP3’
Switch Jumper ‘JMP1’
Control Setting
Jumpers
Settings
Control Setting
Jumpers
Settings
SLM-
5650/5650A
AS SHIPPED
Pins
1 to 2
jumped
CRS-311
AS SHIPPED
Pins
3 to 4
jumped
CDM-750
Pins
3 to 4
jumped
CRS-500
Pins
1 to 2
jumped
4.5
Switch Configuration
4.5.1 Switch Power
Follow
these
steps
to
connect
the
power
cords:
Step
Task
1
Each CRS-311 is supplied with two power cords. Connect the female end of the supplied
power cords (one to each power supply power input).
2
Plug both power cords into the power source(s). The CRS-311 will power ON.
Note: The auto-sensing power supplies do not require any adjustments.
If
only
one
power
supply
module
is
used,
mask
the
fault
for
the
unused
power
supply
as
follows:
Step
Task
1
Go to the CONFIG: MASKS
Æ
SW-ALARMS menu.
2
Select to mask the unused power supply.
The
power
supplies
contain
two
fuses,
one
each
for
line
and
neutral
connections
(or
L1,
L2
where
appropriate).
These
are
contained
within
the
body
of
the
connector,
behind
the
small
plastic
flap.
For
continued
operator
safety,
always
replace
the
fuses
with
the
correct
type
and
rating.
For
115/230
volt
AC
operation,
use
T1A
(slow
‐
blow)
20
mm
fuses.
Summary of Contents for CRS-311
Page 22: ...CRS 311 1 1 Redundancy Switch Revision 7 Preface MN CRS311 IOM xxii Notes...
Page 48: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 2 Notes...
Page 62: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 16 Notes...
Page 128: ...CRS 311 1 1 Redundancy Switch Revision 7 Front Panel Operation MN CRS311 IOM 5 20 Notes...
Page 166: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix A MN CRS311 IOM A 24 Notes...
Page 178: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix B MN CRS311 IOM B 12 Notes...
Page 186: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix C MN CRS311 IOM C 8 Notes...
Page 194: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...