CRS-311 1:1 Redundancy Switch
Revision 7
Front Panel Operation
MN/CRS311.IOM
5–14
•
Replace
defective
power
supply
module;
•
If
the
second
power
supply
module
is
not
needed,
you
can
mask
this
alarm.
SWITCH ALARM: RM PROBLEM
RM I/O TIMEOUT
‐
OR
‐
SWITCH ALARM: MODEM COMMS
PROBLEM, TRAFFIC MODEM
These
Switch
Alarm
screen
examples
show
that
there
are
faults
–
communication
has
been
lost
to
the
Redundant
or
the
Traffic
Modem;
accordingly,
the
front
panel
“
Unit
Status
”
LED
indicator
is
lit
RED
.
Suggested
corrective
actions
include:
•
Check
cable
connections.
See
Chapter
3.
CABLES
AND
CONNECTIONS
.
•
Check
cable
operation.
Ensure
the
cables
are
OK
by
swapping
them
with
others.
For
cable
information
refer
to
Chapter
3.
CABLES
AND
CONNECTIONS
and
Appendix
A.
CABLE
DRAWINGS
.
•
Check
modem
configurations.
See
Chapter
4.
MODEM,
RMI/TMI,
AND
SWITCH
CONFIGURATION
and
the
pertinent
modem’s
Installation
and
Operation
Manual.
SWITCH ALARM: RM PROBLEM
MGC refused, cpde: 12 TFT
This
Switch
Alarm
screen
example
shows
that
there
is
a
fault
–
here,
COMMs
are
good
to
the
Redundant
Modem,
but
the
configuration
of
the
Traffic
Modem
cannot
be
configured
into
the
Redundant
Modem.
The
front
panel
“
Unit
Status
”
is
lit
RED
.
Suggested
corrective
actions
include:
•
Ensure
that
the
most
capable
modem
(latest
hardware
revision,
firmware
version,
FAST
options,
installed
options
e.g.
Turbo
card)
is
set
up
as
the
Redundant
Modem.
The
code
indicates
the
parameter
within
the
modem’s
“MGC”
(Global
Configuration)
remote
command/query
configuration
string
that
is
causing
the
Redundant
Modem
to
refuse
it.
Summary of Contents for CRS-311
Page 22: ...CRS 311 1 1 Redundancy Switch Revision 7 Preface MN CRS311 IOM xxii Notes...
Page 48: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 2 Notes...
Page 62: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 16 Notes...
Page 128: ...CRS 311 1 1 Redundancy Switch Revision 7 Front Panel Operation MN CRS311 IOM 5 20 Notes...
Page 166: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix A MN CRS311 IOM A 24 Notes...
Page 178: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix B MN CRS311 IOM B 12 Notes...
Page 186: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix C MN CRS311 IOM C 8 Notes...
Page 194: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...