CRS-311 1:1 Redundancy Switch
Revision 7
Front Panel Operation
MN/CRS311.IOM
5–15
The
three
‐
letter
instruction
code
is
indicated
also
to
assist
decoding
the
problem
parameter:
►
For
the
CDM
‐
Qx
modem
,
the
code
is
the
decimal
number
indicating
the
problem
parameter
within
its
MGC
configuration
code:
00
NO
ERROR
01
ITF Interface
02
LBO
T1 Line Build-Out
03
FRM
Framing mode
04
TFQ
Tx Frequency
05
TFT
Tx FEC Type
06
TMD
Tx Modulation
07
TCR
Tx FEC Code Rate
08
TDR
Tx Data Rate
09
TSI
Tx Spectrum Invert
10
TSC
Tx Scrambler state
11
TPL
Tx Power Level
12
TCK
Tx Clock
13
TDI
Tx Data Invert
14
TXO
Tx Carrier State
15
AUP
AUPC enable
16
APP
AUPC parameters
17
WUD Warm-Up Delay
18
TXC
Tx common output state
19
TRS
Tx Reed-Solomon
20
TXA
Tx roll-off (alpha) factor
21
TCI
Tx Data Clock Invert
22
RFQ
Rx Frequency
23
RFT
Rx FEC Type
24
RMD
Rx Modulation
25
RCR
Rx FEC Code Rate
26
RDR
Rx Data Rate
27
RSI
Rx Spectrum Invert
28
RDS
Rx DeScrambler state
29
RDI
Rx Data Invert
30
RSW
Rx Sweep Width
31
EBA
Eb/No Alarm point
32
BCS
Rx Buffer clock source
33
RRS
Rx Reed-Solomon
34
RBS
Rx Buffer size/enable
35
RCI
Rx Data Clock Invert
36
ERF
External Reference setting
37
EFM
EDMAC Framing mode
38 ESA
EDMAC Slave Address
range
39
TST
Test mode (read-only)
40
MSK
Alarm Masks
41
RTS
Request-To-Send control
42
SSI
Statistics Sample Interval
43
CNM
CnC Mode
44
CFO
CnC Frequency Offset
45
CSD
CnC Min/Max Search Delay
46
CRA
CnC Re-acquisition Time
See the remote control section in the pertinent modem’s Installation and
Operation Manual for detailed information on the MGC (Global Configuration)
remote command/query.
5.2.4.3 (MONITOR:) STORED EVENTS
STORED EVENTS: VIEW
CLEAR-ALL (PRESS ENTER)
Use
the
◄►
arrow
keys
to
select
VIEW
or
CLEAR
‐
ALL
,
and
then
press
ENTER
.
If
CLEAR
‐
ALL
is
selected,
the
event
log
is
cleared
and
you
are
returned
to
the
previous
menu.
However,
if
there
are
faults
present
on
the
unit
at
this
time,
new
log
entries
are
generated
for
those
faults.
Note
that,
in
accordance
with
international
convention,
the
date
is
shown
in
DAY
‐
MONTH
‐
YEAR
format.
Summary of Contents for CRS-311
Page 22: ...CRS 311 1 1 Redundancy Switch Revision 7 Preface MN CRS311 IOM xxii Notes...
Page 48: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 2 Notes...
Page 62: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 16 Notes...
Page 128: ...CRS 311 1 1 Redundancy Switch Revision 7 Front Panel Operation MN CRS311 IOM 5 20 Notes...
Page 166: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix A MN CRS311 IOM A 24 Notes...
Page 178: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix B MN CRS311 IOM B 12 Notes...
Page 186: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix C MN CRS311 IOM C 8 Notes...
Page 194: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...