CRS-311 1:1 Redundancy Switch
Revision 7
Modem, RMI/TMI, and Switch Configuration MN/CRS311.IOM
4–19
If
the
CDM
‐
Qx/QxL
configuration
includes
Carrier
‐
in
‐
Carrier
®
this
holdoff
time
should
be
no
less
than
8
seconds.
Follow
these
steps
to
set
the
Backup Holdoff Period
:
Step
Task
1
Go to the CONFIG
Æ
HOLDOFFS menu.
2
Change the BACKUP HOLDOFF to any number in the range of 1 to 99 seconds.
4.6.1.2.2
Set Restore Holdoff Period
The
"
Restore
Holdoff
"
setting,
which
is
also
programmable
from
1
to
99
seconds,
determines
the
ability
of
the
Switch
to
automatically
put
the
backed
up
Traffic
Modem
online
again
if
its
fault
clears.
Normally,
the
failed
Traffic
Modem
taken
offline
remains
offline
indefinitely.
If
the
fault
clears,
traffic
will
be
returned
to
the
unit
(in
Auto
mode)
only
if
the
Redundant
Modem
fails.
Follow
these
steps
to
set
the
Restore Holdoff Period
:
Step
Task
1
Go to the CONFIG
Æ
HOLDOFFS menu.
2
Change the RESTORE HOLDOFF to any number in the range of 1 to 99 seconds.
4.6.1.3 Set Alarm Masking
Another
way
to
adjust
the
Switch's
reaction
in
Auto
mode
is
to
mask
modem
faults.
You
may
disable
modem
Rx,
Tx
or
both
fault
types
so
that
the
Switch
does
not
react
to
them.
This
masking
prevents
the
Switch
from
taking
automatic
action
and
prevents
the
logging
of
the
faults
in
the
stored
events
list.
These
masks
are
global
to
all
the
modems
attached
to
the
Switch.
Follow
these
steps
to
set
Alarm Masks
:
Step
Task
1
Go to
CONFIG
Æ
MASKS
Æ
MODEM ALARMS
.
2
Set the mask parameters as desired.
Summary of Contents for CRS-311
Page 22: ...CRS 311 1 1 Redundancy Switch Revision 7 Preface MN CRS311 IOM xxii Notes...
Page 48: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 2 Notes...
Page 62: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 16 Notes...
Page 128: ...CRS 311 1 1 Redundancy Switch Revision 7 Front Panel Operation MN CRS311 IOM 5 20 Notes...
Page 166: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix A MN CRS311 IOM A 24 Notes...
Page 178: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix B MN CRS311 IOM B 12 Notes...
Page 186: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix C MN CRS311 IOM C 8 Notes...
Page 194: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...