CRS-311 1:1 Redundancy Switch
Revision 7
Serial-based Remote Product Management
MN/CRS311.IOM
6–10
Parameter Type
Command
(Code and
qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes:
i.e., ASCII codes between 48 and 57)
Response to Command
(Target-to-Controller)
Query
(Code and qualifier)
Response to query
(Target-to-Controller)
Clear All Stored
Events
CAE= None
Command
only.
Instructs the unit to clear all Stored Events.
This command takes no arguments.
CAE= (message OK)
CAE* (message OK, but not
permitted in current mode)
N/A
N/A
Config Load
CLD=
1 byte, numerical, 0
to 9
Command only.
Forces the Switch to retrieve the Configuration Memory location
defined by the argument n (0 to 9) and to re-program the Switch
with that stored configuration.
CLD= (message OK)
CLD? (received OK, but
invalid arguments found)
CLD* (message OK, but the
memory location does not
contain configuration info)
N/A
N/A
Config Store
CST=
1 byte, numerical, 0
to 9
Command or Query.
The command forces the Switch to store its current configuration in
the Configuration Memory location defined by the argument n (0 to
9).
Example: CST=4 (Store current configuration in location 4)
WARNING: Use with caution! If the location already contains data,
it will be automatically overwritten. If in doubt, query the location
first.
The query returns the contents of the location.
CST= (message OK)
CST? (received OK, but
invalid arguments found)
CST* (message OK, but not
permitted in current mode)
CST?n
where n is 0 to 9
Returns the same format as
the SGC, with the form:
CST=xxx....xxx for a valid
config, and
CST* where no valid config
is found
Date
DAY=
6 bytes, numerical Command or Query.
The date, in the form ddmmyy (international date convention),
where:
dd = day of the month, between 01 and 31,
mm = month of the year, between 01 and 12, and
yy = year, between 97 and 96 (1997 to 2000, then 2000 to 2096)
Example: DAY=240457 would be April 24, 2057.
DAY= (message OK)
DAY? (received OK, but
invalid arguments)
DAY* (message OK, but not
permitted in current mode)
DAY?
DAY=ddmmyy
(see description of
arguments)
Equipment ID
N/A
4 bytes, alpha-
numeric
Query only.
Unit returns information concerning the equipment identification.
S311 indicates this CRS-311 1:1 Switch unit.
(S300 indicates CRS-300 1:N Switch).
N/A EID?
EID=xxxx
(see description of
arguments)
Summary of Contents for CRS-311
Page 22: ...CRS 311 1 1 Redundancy Switch Revision 7 Preface MN CRS311 IOM xxii Notes...
Page 48: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 2 Notes...
Page 62: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 16 Notes...
Page 128: ...CRS 311 1 1 Redundancy Switch Revision 7 Front Panel Operation MN CRS311 IOM 5 20 Notes...
Page 166: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix A MN CRS311 IOM A 24 Notes...
Page 178: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix B MN CRS311 IOM B 12 Notes...
Page 186: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix C MN CRS311 IOM C 8 Notes...
Page 194: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...