Parameter Type
Command
(Code and
qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes:
i.e., ASCII codes between 48 and 57)
Response to Command
(Target-to-Controller)
Query
(Code and qualifier)
Response to query
(Target-to-Controller)
Faults and Status N/A
15 bytes, alpha-
numeric
Query only.
Unit returns the current fault and status codes for the Switch itself,
where:
r = Redundant Modem:
0 = OK,
1 = RMI not present
2 = RM I/O timeout
3 = RM comms problem
4 = RM is in a test mode
5= RM is rejecting an MGC configuration string
Power supply information, values 0 or 1 only.
A/a = + 5V PSU-A under/over
B/b = +5V PSU-B under/over
C/c = +12V PSU-A under/over
D/d = +12V PSU-B under/over
E/e = -12V PSU-A under/over
F/f = -12V PSU-B under/over
m is TMI: interface mismatch:
0 = no problem, 1 indicates the TM position of a TMI interface
mismatch
i is modem I/O communications:
0 = no problem, 1 indicates the traffic modem is activated but is not
responding.
N/A FLT?
FLT=rAaBbCcDdEeFfmi
(see description of
arguments)
Independent
Mode
IMS=
1 byte, value of 0
or 1
Command or Query.
x indicates the normal/Independent Mode operational status of the
Switch:
0 = normal operation
1 = Independent Mode enabled
IMS= (message OK)
IMS? (received OK, but
invalid arguments found)
IMS?
IMS=x
(see description of
arguments)
Local/ Remote
Status
LRS=
1 byte, value of 0
or 1
Command or Query.
x indicates the local/remote status of the Switch:
0 = local
1 = remote
LRS= (message OK)
LRS? (received OK, but
invalid arguments found)
LRS?
LRS=x
(see description of
arguments)
Modem Alarm
Mask
MAM=
1 byte, numerical
Command or Query.
x indicates the Modem alarm mask:
0 = no faults masked
1 = Tx faults masked
2 = Rx faults masked
MAM= (message OK)
MAM? (received OK, but
invalid arguments found)
MAM* (message OK, but not
permitted in current mode)
MAM?
MAM=x
(see description of
arguments)
Summary of Contents for CRS-311
Page 22: ...CRS 311 1 1 Redundancy Switch Revision 7 Preface MN CRS311 IOM xxii Notes...
Page 48: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 2 Notes...
Page 62: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 16 Notes...
Page 128: ...CRS 311 1 1 Redundancy Switch Revision 7 Front Panel Operation MN CRS311 IOM 5 20 Notes...
Page 166: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix A MN CRS311 IOM A 24 Notes...