CRS-311 1:1 Redundancy Switch
Revision 7
Installation
MN/CRS311.IOM
2–6
2.2.2 Installing the Modem Optional Side-Mounting Bearingless Rack Slide
Set
The
optional
FP/SL0006
Bearingless
Rack
Slide
Set
may
be
installed
into
the
equipment
rack
cabinet
and
onto
the
sides
of
each
CDM
‐
Qx/QxL
or
SLM
‐
5650/A
as
shown
in
Figure
2
‐
4
and
per
the
following
procedure:
Step
Task
1
Use the provided mounting hardware to install one slide onto each side of the modem
chassis.
2
Use the provided mounting hardware to install the slide rail components into each interior
side of the equipment rack cabinet.
3
Mount the unit into the front of the equipment rack. Ensure that the slides properly engage
the cabinet-mounted slide rails.
4
Continue to slide the modem into the equipment rack to its final operating position. Then,
use four user-provided screws to secure the modem to the equipment rack’s right and left
threaded front mounting rails (through the front panel mounting slots).
CEFD Part Number
Description
FP/SL0006
Bearingless Rack Slide Set – 26”
Figure 2-4. Installing the Modem Optional Bearingless Rack Slide Set
Summary of Contents for CRS-311
Page 22: ...CRS 311 1 1 Redundancy Switch Revision 7 Preface MN CRS311 IOM xxii Notes...
Page 48: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 2 Notes...
Page 62: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 16 Notes...
Page 128: ...CRS 311 1 1 Redundancy Switch Revision 7 Front Panel Operation MN CRS311 IOM 5 20 Notes...
Page 166: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix A MN CRS311 IOM A 24 Notes...
Page 178: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix B MN CRS311 IOM B 12 Notes...
Page 186: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix C MN CRS311 IOM C 8 Notes...
Page 194: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...