CRS-311 1:1 Redundancy Switch
Revision 7
Serial-based Remote Product Management
MN/CRS311.IOM
6–12
Parameter Type
Command
(Code and
qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes:
i.e., ASCII codes between 48 and 57)
Response to Command
(Target-to-Controller)
Query
(Code and qualifier)
Response to query
(Target-to-Controller)
Modem type
N/A
4 bytes, numeric
Query only.
Unit returns information concerning the model of the Redundant
Modem attached, where xxxx may be
5650 indicating the SLM-5650 modem.
N/A MOD?
MOD=xxxx
(see description of
arguments)
Number of Unread
Stored Events
N/A
2 bytes, numerical Query only.
Switch returns the number of Stored Events, which remain unread,
over the remote control. Viewing the stored events from the front
panel of the modem does not affect this value.
Example: NUE=98
N/A NUE?
NUE=xx
(see description of
arguments)
Operating Mode
OPM=
1 byte, numerical
Command or Query.
x indicates the operating mode, where:
0 = manual mode
1 = auto mode
OPM= (message OK)
OPM? (received OK, but
invalid arguments)
OPM* (message OK, but not
permitted in current mode)
OPM?
OPM=x
(see description of
arguments)
Retrieve Next 5
unread Stored
Events
N/A
80 bytes
Query only.
Switch returns the oldest 5 Stored Events, which have not yet been
read over the remote control.
Reply format:
[cr]Sub-body[cr]Sub-body[cr]Sub-body[cr]Sub-body[cr]Sub-body,
where Sub-body=KLMddmmyyhhmmss,
K is the fault/clear indicator, where
F = Fault,
C = Clear,
I = Info
L is the faulting/clearing unit, values:
1 through 9, A =TM,
B=RM,
C=Switch,
D=Info
M is the fault code, where the value depends on faulting unit:
Switch codes are 1 to F, indicating the position of the fault within
the FLT string.
Modem codes are: 1= Unit, 2= Rx traffic, 3= Tx traffic
Info codes are: 0= Power off, 1= Power on, 2= Log cleared
ddmmyy is the date of the event (international format).
hhmmss is the time of the event.
If there are no new events, the unit replies with RNE*.
If fewer than 5 events remain, the last positions are filled with
zeroes.
N/A RNE?
RNE=[cr]KLMddmmyyhhmm
ss[cr]KLMddmmyyhhmmss[c
r]KLMddmmyyhhmmss[cr]KL
Mddmmyyhhmmss[cr]KLMdd
mmyyhhmmss
(see description of
arguments)
Summary of Contents for CRS-311
Page 22: ...CRS 311 1 1 Redundancy Switch Revision 7 Preface MN CRS311 IOM xxii Notes...
Page 48: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 2 Notes...
Page 62: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 16 Notes...
Page 128: ...CRS 311 1 1 Redundancy Switch Revision 7 Front Panel Operation MN CRS311 IOM 5 20 Notes...
Page 166: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix A MN CRS311 IOM A 24 Notes...
Page 178: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix B MN CRS311 IOM B 12 Notes...
Page 186: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix C MN CRS311 IOM C 8 Notes...
Page 194: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...