Infortrend
5-37
5.14
Controller Parameters
Controller Name
Select “View and Edit Config Parms” from
the main menu. Choose “View and Edit
Configuration parameters,” “Controller
Parameters," then press
ENT
. The current
name will be displayed. Press
ENT
for two
seconds and enter the new controller name
by using
▼
or
▲
. Press
ENT
to move to
another character and then press
ENT
for
two seconds on the last digit of controller
name to complete the process.
LCD Title Display Controller Name
Choose “View and Edit Configuration
parameters,” “Controller Parameters,”
then press
ENT
. Use
▼
or
▲
to choose to
display the embedded controller logo or
any given name on the LCD initial screen.
Password Validation Timeout
Choose “View and Edit Configuration
parameters,” “Controller Parameters,”
then press
ENT
. Select “Password
Validation Timeout,” and press
ENT
.
Press
▼
or
▲
to choose to enable a
validation timeout from one to five
minutes to always check. The always
check timeout will disable any
configuration change without entering the
correct password.
Controller Unique Identifier
Choose “View and Edit Configuration
parameters,” “Controller Parameters,"
then press
ENT
. Press
▼
or
▲
to select
Enter Ctlr Name:
Controller Name:
_ _ _ _
LCD Title Disp –
Controller Logo?
LCD Title Disp –
Controller Name?
PasswdValidation
Timeout-5 mins..
Ctlr Unique
ID-