Infortrend
3-2
3.1.1
Configuring RS-232C Connection via Front Panel
Take the following steps to change the baud rate using the front
panel keypad:
Press
ENT
for two seconds to enter the
Main Menu. Press
▼
or
▲
to select
"View and Edit Configuration ..", then
press
ENT
.
Select "Communication Parameters ..",
then press
ENT
.
Select "RS-232 Configuration ..", then
press
ENT
.
Select "COM1 Configuration ..", then
press
ENT
.
Select "Baud-rate 38400 ..", then press
ENT
.
The baud rate default is 38400. If other
baud rate is preferred, press
▼
or
▲
to
select the baud rate, then press
ENT
for 2
seconds to confirm the selected baud
rate. Set identical baud rate to your
RAID array and your terminal computer.
•
The following baud rates are available: 2400, 4800, 9600, 19200
and 38400.
•
Terminal connection should work properly using the above
setting. You may check the following options in your COM port
configuration if you encounter problems:
1.
“Comm Route Dir ..”: The communication route should be
configured as “direct to port” instead of “through PPP”.
2.
“Term Emul. Enab ..”: Make sure the terminal function has
not been accidentally disabled.
View and Edit
Config Parms
↕
Communication
Parameters ..
RS-232C
Configuration ..
COM1
Configuration ..
Baud-rate 38400
..
Baud-rate 38400
Change to 19200?