11
3.3.3 Insert strength member(s) into lug and
hand
tighten screw
with the tool provided
. See photo 15.
3.3.4 Cut perforated foil into 3 pieces (note orientation) and form over cable. If Flat Drop, wrap around drop.
See photos 16-18.
3.3.5 Place 1 pc of perforated foil between the hose clamp and outer sheath of cable. Tighten hose clamp being
sure to keep the screw head positioned under the cable retention assembly in order to avoid interference
when installing closure. See photos 19-20.
3.3.6 Return to Cable Preparation
Section 3.1.6.
Strength members
inserted into lug.
Caution:
Tighten
lug with nut in
downward position.
Photo # 15
If shielded, keep cable positioned as
shown, while tightening hose clamp.
Photo #20
Place foil under hose clamp
Photo #19
Caution:
Tighten
screw, keep
screw in
contained area
1”
1 1/2”
Photo #16
Cut Foil.
Photo #17
Form foil over cable.
Photo #18
If flat drop, wrap foil
around drop.
Mini
-
OTE 300 Installation Guide
All
trademarks used in this publication are CommScope registered
201
9
CommScope Inc. All rights Reserv
ed