Mini-OTE 300 Installation Guide
All trademarks used in this publication are CommScope registered
201
9
CommScope Inc. All rights Reserved
65
Photo #249
Photo #250
Place foil under hose clamp
9.3.2 Insert strength member(s) into lug and hand tighten screw with the tool provided. See photo 245.
9.3.4 Cut perforated foil into 3 pieces (note orientation) and form over cable. If Flat Drop, wrap around drop.
See photos 246-248.
9.3.5 Place 1 pc of perforated foil between the hose clamp and outer sheath of cable. Tighten hose clamp being
sure to keep the screw head positioned under the cable retention assembly in order to avoid interference
when installing closure. See photos 249-250.
9.3.6 Return to Cable Preparation
Section 9.1.9.
Strength members
inserted into lug.
Photo # 245
1”
1 1/2”
Photo #246
Cut Foil.
Photo #247
Form foil over cable.
Photo #248
If flat drop, wrap foil
around drop.
Caution:
Tighten lug
with nut in
downward position
Caution:
Tighten screw,
keep screw in contained
area.
Caution:
If shielded, keep cable
positioned as shown, while
tightening hose clamp.