8.2 CABLE & EXTERNAL GROUNDING
8.2.1 For cable with shielding, remove a
section of the outer sheath 180
⁰
around the cable by
1.0”
in length
measured from the end of the outer sheath in order to expose cable shielding. See photo 200.
8.2.2 For grounding, press ground bar into slot in closure. If using Inline configuration, install inline ground bar and
secure with bolt. See photo 201.
8.2.3 External ground connection is to be placed in designated location.
The ground wire is to be secured using the
same bolt that is used to secure the cable retention assembly. See photo 202.
Caution:
Do not use braided or stranded ground wire when installing a ground through a port on the
Mini-OTE 300 closure. A solid ground wire is required to prevent a leak path and make a proper seal.
1”
Photo #200
180
⁰
Inline ground bar placed on top of
standard ground bar & secured with bolt
Inline ground bar placed under cable
retention assembly & secured with bolt
Insert ground bar
into slot in
closure.
Photo # 201
Position for external
ground. Secure with
bolt.
Photo # 202
NOTE:
Exposed
shielding will be
bonded to the cable
retention bracket and
ground bar.