Mini-OTE 300 Installation Guide
All trademarks used in this publication are CommScope registered
201
9
CommScope Inc. All rights Reserved
75
Photo #
290
10.3.4 Place 1 pc of perforated foil between the hose clamp and outer sheath of cable. Tighten hose clamp being
sure to keep the screw head positioned under the cable retention assembly in order to avoid interference
when installing closure. See photos 289-290.
P
hot
o #
289
10.3.5 Return to Cable Preparation
Section 10.1.9.
10.4 FIBER ORGANIZING/STORAGE, ROUTING AND SPLICING
10.4.1 BUTT STUBB (cable end) configuration Ribbon Central Core Tube Shielded/Unshielded
10.4.2 Place one loop of ribbon fiber to be spliced in storage area
10.4.3 Route ribbon to tray entry points and mark ribbon 1” beyond grommet locations. De-ribbonize fiber between
marks. See photos 291-292.
10.4.4 Install ribbon grommets onto ribbon 1” before de-ribbonize point. Install grommets onto routing tray and secure
with cable tie. See photos 293-296
Photo #
292
Slots for
grommets
Mark
ribbon 1”
beyond
grommet
l t
Routing tray
entry points
Butt Stub:
Either a left
side
OR
right
side entry
Photo #
291
Photo #
293
Ribbon grommet
Photo #
294
1”
Fiber de-ribbonized
Photo # 295
Photo # 296
Caution:
Tighten screw,
keep screw in contained
area.
Caution:
If shielded, keep cable
positioned as shown, while
tightening hose clamp.
Caution:
Secure with
cable tie so that it is
oriented as shown in
photo # 296
Place foil under hose clamp