12
3.4 FIBER ORGANIZING/STORAGE, ROUTING AND SPLICING
3.4.1 INLINE EXPRESS (thru) configuration LBT Standard & Micro, Flat Drop with or without Trace wire
3.4.2 Route LBT to be spliced to routing tray. See photo 21.
Note:
Left side LBTs to be routed first. Right side LBTs to cross over LBTs from
left side. Otherwise route buffer tube directly to routing tray.
3.4.3 Place appropriate grommet onto buffer tube. If more than one buffer tube, both may be installed into one
grommet.
Insert into routing tray, sliding grommet to align with retaining groove in routing tray. Secure with
cable tie. See photos 22-26A.
3.4.4 Repeat steps 3.4.2 to 3.4.3 with buffer tube coming from other end of cable.
LBTs routed straight to
routing tray
Photo # 21
Standard
LBT
Photo #22
Micro
LBT
Grommet
Photo # 23
Photo # 24
Routing tray
grommet slot
1” of LBT to
remain beyond
grommet
Photo # 25
Photo # 26
Secure with cable tie
so that it is oriented as
shown in photo # 26A
Photo # 26A
Mini
-
OTE 300 Installation Guide
All
trademarks used in this publication are CommScope registered
201
9
CommScope Inc. All rights Reserv
ed