74
10.3 CABLE RETENTION
10.3.1 Open hose clamp on cable retention assembly. Place cable retention assembly around cable. If cable is
shielded and to be grounded, orient the sheath opening, which exposes the shielding, toward the base of
retention clamp. See photos 283-284.
10.3.2 Insert strength member(s) into lug and hand tighten screw with the tool provided. See photo 285.
10.3.3 Cut perforated foil into 3 pieces (note orientation) and form over cable. If Flat Drop, wrap around drop.
See photos 286-288.
Strength members
inserted into lug.
Photo # 285
1”
1 1/2”
Cut Foil.
Photo # 287
Form foil over cable.
If flat drop, wrap foil
around drop.
Open hose
clamp. Place
around cable.
Cable retention assembly
Photo # 283
Photo # 284
Caution:
Cable sheath opening
positioned downward.
Caution:
Tighten lug
with nut in
downward position
Photo # 288
Photo # 286