66
0
1
Forced to high level
0
1
Forced to high level
1
0
Forced to low
level
1
0
Forced to low
level
1
1
Optional state
1
1
Optional state
Example: output port SigOut2 force output low level, other optional output port status, setting Pn082 parameter value is 8.
number
name
value range
the
default value
unit
apply
Pn083
Low pressure alarm detect amplitude
50~280
200
V
All
◢
When the bus voltage is less than the amplitude, the Pn078 decided whether to send out alarm
.
number
name
value range
the
default value
unit
apply
Pn084
High pressure alarm detect amplitude
290~380V
365
V
All
◢
When the bus voltage is higher than the amplitude, immediately
issued a warning, in order to protect the internal electronic components. Input power supply voltage should be
within the specifications of the acceptable, if slightly on the high side, can be appropriately increase amplitude
detection. If the input voltage power supply has been far beyond specification, shall not increase the parameter
value, otherwise it will damage the driver, please conform to the specifications of the power supply.
number
name
value range
the
default value
unit
apply
Pn085
▲
Motor pole logarithmic
1~100
4
对
All
number
name
value
range
the
default value
unit
apply
Pn086
Renewable circuit discharge cycle
0~2000
70
ms
All
◢
When the servo motor running in generator mode, renewable electricity too