64
number
name
value range
the
default value
unit
apply
Pn078
Lack of voltage detection
0~1
1
All
◢
0
not check
out
◢
1
Check out
number
name
value range
the
default value
unit
apply
Pn079
The system status display project
selection
0-23
0
All
◢
Drive, automatic Dn000 submenu into monitor mode menu. By default, according to the manufacturer to
display the system status (motor speed), the user can set the parameter value, so it shows Dn000 particular
state of the system parameters, details see the list of "monitoring mode".
0
The default system (motor speed)
1
Speed instruction
2
The average torque
3
Position deviation value
4
The ac power voltage
5
Maximum instantaneous torque
6
Pulse input frequency
7
Temperature of
the heat sink
8
The current motor speed
9
Effective input command pulse accumulative total value is low
10
Effective input command pulse accumulative total value is
high
11
Position control,
effective feedback pulse encoder accumulative total value is low
12
Position control, effective feedback pulse encoder
cumulative value high
13
Regenerative braking load factor
14
Input port signal state
15
Signal output port state
16
Analog voltage torque instruction
17
Simulate the speed reference voltage
18
Output function status register
19
After power on the servo, pulse encoder feedback accumulative total value is low
20
After power on the servo, pulse encoder feedback accumulative total value is high
21
number
name
value range
the
default value
unit
apply
Pn080
▲
The encoder to choose
0~1
0
All
◢
0:
Incremental encoder 2500 line
Driver soft ware 22 encoder UVW letter 23 rotor absolute position