MAIN - Programming
By means of a defined frequency there is a switch-over between the two
parameter sets. The appearance of the weld seam surface can be formed by
the defined change of parameters. During root welding, defined cool-down
times can be reached depending on the setting. The "DuoPulse" function is
available for all gas/material combinations.
The characteristic curve is already provided with a 2nd parameter set
which is useful for welding. The display shows "- 0 - "and a corresponding
value for the wire speed in m/min. If you want to deviate from the base
setting, use the rotary knob 3 to enter a value between -99 and +99. The
appropriate absolute value changes as well.
DuoPulse frequency
This function is used to change the switching speed (frequency) of both
parameter sets.
The characteristic curve is already provided with a useful frequency for
welding.
The display shows "- 0 - "and an appropriate value for the frequency in Hz.
If you want to deviate from the base setting, use the rotary knob 3 to enter
a value between -99 and +99. The appropriate absolute value changes as
well.
6.3 Parameters in operating mode Spot Welding / Interval
If the operating mode "Spot welding" is active, you have to enter the values
for the parameters "Spot welding time" and "Pause time" (sec).
Function
Correction value
Gas pre-flow
Off, +/- 99
Inching-in
+/- 99
Start time
Off, +/- 99, tor
Starting power
+/- 99
Upslope
Off, +/- 99
Main power
Absolute value m/min
DuoPulse modulation*
+/- 99
DuoPulse frequency*
+/- 99
Step modulation
+/- 9.9 m/min
Number of steps
Off, 1-10
Downslope
Off, +/- 99
End crater filling time
Off, +/- 99
End crater power
+/- 99
Wire burnback
+/- 99
Gas post-flow
Off, +/- 99
Spot welding time
Absolute value 0-99.9 sec
Interval time
Absolute value 0-99.9 sec
* Display only if the function is active!
A "Spot welding time" between 0...99.9 s can be selected with rotary knob 3.
1,5 s
2,0 s
0,8
1,5 s
0,8 s
Brenner
Tastendruck
1,5 s
Punktzeit
Punktzeit
Punktzeit
Durch früheres Lösen der Brennertaste
wird der Schweißvorgang abgebrochen !
Schweißzeit
Punktzeit = 1,5 s
1,5 s
2,0 s
0,8
1,5 s
0,8 s
Brenner
Tastendruck
1,5 s
Punktzeit
Punktzeit
Punktzeit
Durch früheres Lösen der Brennertaste
wird der Schweißvorgang abgebrochen !
Schweißzeit
Punktzeit = 1,5 s
Figure 13.
Spot welding time
Summary of Contents for NexT 452 AC
Page 4: ......
Page 11: ...11 Block 1 Operational Safety...
Page 27: ...27 Block 2 Basic information Qineo NexT...
Page 110: ...110 Job mode...
Page 148: ...148...
Page 149: ...149 Block 4 Additional information...
Page 164: ...164 SD module...
Page 191: ...191 Block 6a Error messages...
Page 207: ...207 Block 6b General maintenance instructions...
Page 212: ...212...
Page 213: ...213 Block 7 Automation...
Page 232: ...232...
Page 233: ...233...
Page 234: ...www qineo de...