![Cloos NexT 452 AC Operating Instructions Manual Download Page 34](http://html1.mh-extra.com/html/cloos/next-452-ac/next-452-ac_operating-instructions-manual_2625802034.webp)
34
Type: QINEO NexT
6. Technical data
Type: QINEO NexT
NexT 452
NexT 452 AC
Ambient conditions
Operating temperature
°C
-10°C…+40°C
Storage temperature
°C
-25°C…+55°C
Humidity
50% at 40°C
90% at 20°C
Ambient air
Free of unusual dust
Free of aggressive media
Welding range
25A/15V-450A/36.5V
EMC
Class
A
Open circuit voltage
at 400V input voltage
(V)
80.0
75.0
Data 60% duty cycle
I2 60% secondary
(A)
450
450
U2 60% secondary
(V)
36.5
36.5
I1 60% primary
(A)
30.5
32.5
S1 60% primary
(kVA)
21.1
22.5
Data 100% duty cycle
I2 100% secondary
(A)
350
350
U2 100% secondary
(V)
31.5
31.5
I1 100% primary
(A)
22
22.6
S1 100% primary
(kVA)
14.8
15.7
Mains voltage 1
(V)
3/PE 380…480V 50/60Hz
3/PE 400V
Fuse 1 (slow or "D")
(A)
32
Further data
Connection cable
4x6
Type of protection
IP23
Type of cooling
F
Insulation class
F
Noise emission value in idle running
dB(A)
=< 70
Dimensions:(L x W x H)
(mm)
819 x 342 x 498 (+55 for lifting eyes) 891 x 342 x 727 (+55 for lifting eyes)
Weight with pedestals:
(kg)
67
99
You find the technical data of the wire drive units in block 5 "QWD".
Summary of Contents for NexT 452 AC
Page 4: ......
Page 11: ...11 Block 1 Operational Safety...
Page 27: ...27 Block 2 Basic information Qineo NexT...
Page 110: ...110 Job mode...
Page 148: ...148...
Page 149: ...149 Block 4 Additional information...
Page 164: ...164 SD module...
Page 191: ...191 Block 6a Error messages...
Page 207: ...207 Block 6b General maintenance instructions...
Page 212: ...212...
Page 213: ...213 Block 7 Automation...
Page 232: ...232...
Page 233: ...233...
Page 234: ...www qineo de...