194
No. Error message on the display
Possible cause
Remedy
21 Low water flow rate
Optional machine equipment.
Water flow rate lower than limit
value (lines too long).
Option water monitoring, check water
flow rate
Check limit values
Refill coolant, if required.
Ventilate pump.
Check cooling circuit
Service
22 High water temperature
Optional machine equipment.
Water temperature higher than
limit value.
Option water monitoring, check water
temperature
Check limit values
Refill coolant, if required.
Ventilate pump
Service
23 Arc failure "Process phase"
Arc interruption during the
welding process. During welding,
the arc parameters fall below
a certain level for more than 1
second.
Check process settings
Check wire drive unit
Check gas
Deactivate process monitoring
Service
24 Arc failure "Ignition phase"
If the arc does not burn within 5
seconds after the start signal.
Check welding wire / wire drive unit
Service
39
Robot software version out-
of-date
Software update required.
Software update
Service
41
Software version remote
control out-of-date
Software update required.
Software update
Service
44
Software version VBC
DeviceNet out-of-date
Software update required.
Software update
Service
45 VBC DeviceNet module failed
Communication between control
and DeviceNet module faulty.
Switch machine Off and On
Check plug and connections (CAN BUS)
Service
46 VBC DeviceNet bus failed
Communication between
DeviceNet Master and module
(Slave) faulty.
Switch machine Off and On
Check plug and connections
(DeviceNet)
Service
47
Software version VBC
ProfiNet out-of-date
Software update required.
Switch machine Off and On
Check plug and connections
Service
48 VBC ProfiNet module failed
Communication between control
and ProfiNet module faulty.
Switch machine Off and On
Check plug and connections (CAN BUS)
Service
49 VBC ProfiNet bus failed
Communication between control
and ProfiNet module faulty.
Switch machine Off and On
Check plug and connections (ProfiNet)
Service
50 VBC Profibus failed
Communication between control
and ProfiNet module faulty.
Switch machine Off and On
Check plug and connections (ProfiNet)
Service
51 QWD1 failed
CAN connection interrupted.
Switch machine Off and On
Check plug and connections
Service
Summary of Contents for NexT 452 AC
Page 4: ......
Page 11: ...11 Block 1 Operational Safety...
Page 27: ...27 Block 2 Basic information Qineo NexT...
Page 110: ...110 Job mode...
Page 148: ...148...
Page 149: ...149 Block 4 Additional information...
Page 164: ...164 SD module...
Page 191: ...191 Block 6a Error messages...
Page 207: ...207 Block 6b General maintenance instructions...
Page 212: ...212...
Page 213: ...213 Block 7 Automation...
Page 232: ...232...
Page 233: ...233...
Page 234: ...www qineo de...