4.1.1 Synchronisation mode
Programmieren
–
Impulssync.
Programmieren
Impulssynchronisation -
Taktgeber
Puls Extern Job 101
PULS ALTERN.
V
0
A
1.2 mm Fe
82% Argon 18% Co
2
0.0
Synchronisations-Modus
Taktgeber
Phasenverschiebung
Alternierend
50%
Name
Function
"Pulse generator"
The pulse cycle of the welding power source is
available for synchronisation.
"Pulse receiver"
The welding power source executes its pulses at the
configured time depending on the pulse generator.
"Asynchronous"
The allocation of pulse generator and pulse receiver is individually
determined for each weld seam.
• If a welding power source starts welding earlier or if a weld is longer,
you have to configure this machine as pulse generator.
• When the welding times and the weld lengths are the same, a pulse
generator can be freely allocated.