![Cloos NexT 452 AC Operating Instructions Manual Download Page 18](http://html1.mh-extra.com/html/cloos/next-452-ac/next-452-ac_operating-instructions-manual_2625802018.webp)
18
Safety specifications for MIG/MAG welding machines
3.3.6. Noise
• Noise may cause permanent damage to your hearing. During welding the
admissible noise level might be exceeded under unfavourable conditions.
• Please make sure that the admissible maximum values are not exceeded
(Security Administrator).
• If the maximum values are exceeded, a suitable ear protection (earplugs
or earmuffs) has to be used.
3.4 Electrical danger due to mains current and welding current
3.4.1. General information
An electric shock can prove fatal. Basically, every electric shock is
extremely
dangerous
.
• Do
not
touch live parts within or outside the power source!
• During MIG/MAG welding, the welding wire, the wire coil, the drive rollers
as well as all metal parts which touch the welding wire, are live.
• All cables must be tight, undamaged, insulated and sufficiently dimen-
sioned. The negative cable (earth cable) and the positive cable are locked
by turning to the right. Loose plugs affect the arc and thus the welding
behaviour of the power source to a
considerable
extent.
• Switch the welding machine off when not in use to prevent any electrical
risk.
• Avoid contact with metal parts, wear dry, insulating clothing and safety
shoes.
• Power sources may only be used when
all
covers are available and correctly
installed.
3.4.2. Mains connection
The power supply must be installed by
qualified personnel
only!
Please ensure that the mains voltage to be used is identical to the operating
voltage indicated on the machine type plate.
According to the connection regulations the machine has to be fused and
connected by means of a mains cable. You will find the connection rules
inside the power source after removal of the cover or side panel. The cross
section of the connection cable must be adequate.
The machine must be connected to a three-phase four-wire system with
earth conductor and operated.
WARNING!
INFO!
CAUTION!
Summary of Contents for NexT 452 AC
Page 4: ......
Page 11: ...11 Block 1 Operational Safety...
Page 27: ...27 Block 2 Basic information Qineo NexT...
Page 110: ...110 Job mode...
Page 148: ...148...
Page 149: ...149 Block 4 Additional information...
Page 164: ...164 SD module...
Page 191: ...191 Block 6a Error messages...
Page 207: ...207 Block 6b General maintenance instructions...
Page 212: ...212...
Page 213: ...213 Block 7 Automation...
Page 232: ...232...
Page 233: ...233...
Page 234: ...www qineo de...