![Cloos NexT 452 AC Operating Instructions Manual Download Page 195](http://html1.mh-extra.com/html/cloos/next-452-ac/next-452-ac_operating-instructions-manual_2625802195.webp)
195
No. Error message on the display
Possible cause
Remedy
52 QWD2 failed
CAN connection interrupted.
Switch machine Off and On
Check plug and connections
Service
53 QWD3 failed
CAN connection interrupted
Switch machine Off and On
Check plug and connections
Service
54 QWD4 failed
CAN connection interrupted.
Switch machine Off and On
Check plug and connections
Service
55 DSP1 failed
CAN connection interrupted.
Switch machine Off and On
Check plug and connections
Service
57 IO module 1 failed
CAN connection interrupted.
Switch machine Off and On
Check plug and connections
Service
58 IO module 2 failed
CAN connection interrupted.
Switch machine Off and On
Check plug and connections
Service
59 VBC Profibus module failed
CAN connection interrupted.
Switch machine Off and On
Check plug and connections
Service
60
Software version operating
module out-of-date
Software update required.
Software update
Service
61
Software version QWD1 out-
of-date
Software update required.
Software update
Service
62
Software version QWD2 out-
of-date
Software update required.
Software update
Service
63
Software version QWD3 out-
of-date
Software update required.
Software update
Service
64
Software version QWD4 out-
of-date
Software update required.
Software update
Service
65
Software version DSP 1 out-
of-date
Software update required.
Software update
Service
67
Software version IO module 1
out-of-date
Software update required.
Software update
Service
68
Software version IO module 2
out-of-date
Software update required.
Software update
Service
69
Software version VBC
Profibus out-of-date
Software update required.
Software update
Service
72 Robot communication failed
CAN connection interrupted
between robot controller and
welding power source.
Switch machine Off and On
Check plug and connections
Service
73 No communication with DSP
Interruption in the CAN bus of
the welding power source.
Check plug and connections
Service
Summary of Contents for NexT 452 AC
Page 4: ......
Page 11: ...11 Block 1 Operational Safety...
Page 27: ...27 Block 2 Basic information Qineo NexT...
Page 110: ...110 Job mode...
Page 148: ...148...
Page 149: ...149 Block 4 Additional information...
Page 164: ...164 SD module...
Page 191: ...191 Block 6a Error messages...
Page 207: ...207 Block 6b General maintenance instructions...
Page 212: ...212...
Page 213: ...213 Block 7 Automation...
Page 232: ...232...
Page 233: ...233...
Page 234: ...www qineo de...