![Cloos NexT 452 AC Operating Instructions Manual Download Page 127](http://html1.mh-extra.com/html/cloos/next-452-ac/next-452-ac_operating-instructions-manual_2625802127.webp)
127
If a setting range can be adjusted, the input position is shown with a blue
cursor.
2. Press a rotary knob to select a setting range.
3. Turn a rotary knob to change the selected setting range.
In general:
• The minimum and maximum start power and end crater power are
input as correction value (-99 to +99).
• The minimum and maximum main power is input in m/min as abso-
lute value.
4. Press the rotary knob again to jump to the next setting range.
5. Leave the setting ranges by pressing a rotary knob as long as the cursor
is on the graphical characteristic curve again.
4.2.6.2 Activating the setting ranges
If activated, the note "Limit" is shown on the main display.
The setting ranges are active as soon as you have logged on with the "Pro-
grammer" operating level.
For the operating level "Automatic" the function "Fine" must be enabled
in the user management to activate the setting ranges for arc length and
dynamics. If the function "Power" is enabled in addition, the setting ranges
for start, main and end crater power are also active.
All other adjustment
parameters are blocked.
Blue bars at the bottom of the main display show the relative position of
the setting value within the setting range.
4.2.6.3 Deactivating the setting ranges
In order to configure the setting ranges, log on with the operating level
"Configurator". The setting ranges are configured via the configuration
menu of the secondary parameters, see chapter "4.2 Configuration of char-
acteristic curve" on page 124.
Turn a rotary knob to jump to the next or previous input position.
1. Use a rotary knob to select the start, main or end crater power.
If a setting range can be adjusted, the input position is shown with a blue
cursor.
2. Press a rotary knob to select a setting range.
3. Turn a rotary knob until the "Off" position to deactivate the selected
setting range.
4. Press the rotary knob again to jump to the next setting range.
5. Leave the setting ranges by pressing a rotary knob as long as the cursor
is on the graphical characteristic curve again.
INFO!
INFO!
Summary of Contents for NexT 452 AC
Page 4: ......
Page 11: ...11 Block 1 Operational Safety...
Page 27: ...27 Block 2 Basic information Qineo NexT...
Page 110: ...110 Job mode...
Page 148: ...148...
Page 149: ...149 Block 4 Additional information...
Page 164: ...164 SD module...
Page 191: ...191 Block 6a Error messages...
Page 207: ...207 Block 6b General maintenance instructions...
Page 212: ...212...
Page 213: ...213 Block 7 Automation...
Page 232: ...232...
Page 233: ...233...
Page 234: ...www qineo de...