![Cloos NexT 452 AC Operating Instructions Manual Download Page 25](http://html1.mh-extra.com/html/cloos/next-452-ac/next-452-ac_operating-instructions-manual_2625802025.webp)
25
If
the air entrance ports of the power source are provided with
air filter mats
,
it should be considered that the
duty cycle
of the power sources reduces
in dependence of the increasing degree of soiling of the air filter mat. The
cleaning interval
for the air filter mat must be determined as experience
shows because the pollution of the filter mat depends on the ambient
conditions. The power sources
must
be operated with air filter mats, if
environmental conditions with increased fuses, aerosols, metal dust etc. are
concerned. The user must regularly check the degree of soiling of the filter
mat. Dirty filters must be replaced!
Oil-contaminated filter mats can cause a fire due to flying sparks (grinding)!
• A
safety check
of the power source is required at least every 12 months. A
repeat check must be carried out by a skilled electrician. A check list with
the individual points to be checked can be provided by the manufacturer.
• Please observe the national and international standards and regulations
regarding the safety check.
• The mounting area should be free of dust and aggressive agents.
• The ground should be horizontal and flat (admissible inclination angle
max. 10º).
• The distance between power source and environment should at least be
0.50
m to allow the cooling air to circulate unhindered.
• The cooling air inlets and outlets must not be blocked by things such as
welder’s apron, tissues, drawings, walls etc.
The admissible ambient temperature may vary from
-10°C
to
+40°C.
Relative air humidity:
up to
50%
at
40°
C (thawing excluded)
up to
90%
at
20°
C (thawing excluded)
The protection class
IP 23
does not allow to install the machine in the rain.
If required, the machine must be covered on a large surface. In the process,
ensure that the through-flow of cooling air is not impaired.
The machine should be stored in a dry and clean room. The ambient
temperatures must not exceed -20
0
C and +45
0
C.
In case of a longer storage, the machine should be covered with a suitable
foil.
ATTENTION!
DANGER!
4. Environmental circumstances
4.1 Storage
Summary of Contents for NexT 452 AC
Page 4: ......
Page 11: ...11 Block 1 Operational Safety...
Page 27: ...27 Block 2 Basic information Qineo NexT...
Page 110: ...110 Job mode...
Page 148: ...148...
Page 149: ...149 Block 4 Additional information...
Page 164: ...164 SD module...
Page 191: ...191 Block 6a Error messages...
Page 207: ...207 Block 6b General maintenance instructions...
Page 212: ...212...
Page 213: ...213 Block 7 Automation...
Page 232: ...232...
Page 233: ...233...
Page 234: ...www qineo de...