![Cloos NexT 452 AC Operating Instructions Manual Download Page 202](http://html1.mh-extra.com/html/cloos/next-452-ac/next-452-ac_operating-instructions-manual_2625802202.webp)
202
No. Error message on the display
Possible cause
Remedy
514
Protective conductor
monitoring
Current in the protective
conductor exceeded
Wiring error
Service
516
Error primary current
transformer
Primary current sensor for
monitoring the symmetrical
supply.
Service
517 Error 24V outputs
24V for pre-load (X21) and QWD
(X8)
Service
518 Error 24V outputs
24V cooling module (X5) and
peripherals (X6)
Service
519
Software version PLD out-of-
date
Incomplete software update
Service
520
…
529
Temperature sensor power
unit defective !
Cable break, short-circuit,
incomplete plug connection
Service
530
Temperature difference heat
sink
Difference between temperature
sensor on primary and secondary
side too large
Service
531
Temperature difference heat
sink AC module
Difference between temperature
sensor on primary and secondary
side too large
Service
532 Incorrect device coding
Device type not recognised
Service
533 Wrong power class
Unknown power class
Service
534
Error when loading the
alignment values
The set values do not match the
checksum.
Service
535 Error inverter PLD!
Only for CW processes: Error
during re-ignition after
polarity change. Check welding
parameters (arc interruptions
due to arc blow?)
Switch machine Off and On
Check plug and connections
Service
536
…
541
Temperature sensor AC
module defective!
Cable break, short-circuit,
incomplete plug connection
Service
544
Excess temperature AC
module
Overheating of the module,
Device dirty
Let the machine cool down
Check filter mats and change if
necessary
Clean machine with dry air
Clean heat sink
Check sensors (service)
553 Driver coding faulty
Version of driver hardware and
software do not match.
Update to suitable software version via
Service
554 Primary overcurrent
Error in inverter
The error is reset after approx. one
minute.
Service
555
Transmission error control
PCU
Interface between control and
PCU faulty.
Service
580 Overflow BMP memory
Memory area for image files is
faulty. (MasterPlus)
Service
581 Overflow BMP address
Memory area for image files is
faulty. (MasterPlus)
Service
Summary of Contents for NexT 452 AC
Page 4: ......
Page 11: ...11 Block 1 Operational Safety...
Page 27: ...27 Block 2 Basic information Qineo NexT...
Page 110: ...110 Job mode...
Page 148: ...148...
Page 149: ...149 Block 4 Additional information...
Page 164: ...164 SD module...
Page 191: ...191 Block 6a Error messages...
Page 207: ...207 Block 6b General maintenance instructions...
Page 212: ...212...
Page 213: ...213 Block 7 Automation...
Page 232: ...232...
Page 233: ...233...
Page 234: ...www qineo de...