![Cloos NexT 452 AC Operating Instructions Manual Download Page 216](http://html1.mh-extra.com/html/cloos/next-452-ac/next-452-ac_operating-instructions-manual_2625802216.webp)
216
2. QIROX Technology Interface (QTI)
2.1 Software compatibility
Depending on the software version of the QINEO welding power source, a
distinction is made between protocol type 1 and protocol type 2.
• QINEO welding power sources with a software version lower than
X.11.XX support the protocol type 1.
• QINEO welding power sources with a software version equal or higher
than X.11.XX and welding power sources type Qineo NexT support the
protocol type 2.
• From QIROX software version V 8.1 on, valid from 25.09.2015, the robot
controller recognises the software version on the welding power source
and automatically selects the protocol type.
2.2 Assignment of protocol type for Tandem operation
Software version Master
Software version
Slave
Protocol type
>=xx.11.xx
>=xx.11.xx
Protocol type 2
< xx.11.xx
< xx.11.xx
Protocol type 1
< xx.11.xx
>=xx.11.xx
Protocol type 1
>=xx.11.xx
< xx.11.xx
Error situation
It must be observed that in Tandem operation, welding power sources
with the protocol type 1 only support the Tandem process "Tandem job
selection". Welding power sources with protocol type 2 support additional
welding processes such as "Tandem f/-f".
2.3 Additional welding processes protocol type 2
Processes
Synergy mode
Expert
mode
CW-S-Pulse
x
Cutting
Tandem job selection
x
x
Tandem f/-f*
x
x
* Tandem f/-f stands for leading / following and is specified by the addi-
tional parameter "Auto. Tandem change of direction". For the automatic
reversal of direction, the leading and the following wire must be specified.
The specification is entered in the TCP window. Hereby, in the event of a
reversal of the direction of welding, the welding parameters for leading
and following wire are switched. For further information, please refer to
the QIROX programming manual, Block 7a, chapter "Tandem f/-f".
2.4 Control of communication between welding power source
and robot
The connection status is displayed in the menu "Diagnostics (2)" -> "Robot".
Read more information in chapter “Diagnostics - Robot” on page 99.
INFO!
Summary of Contents for NexT 452 AC
Page 4: ......
Page 11: ...11 Block 1 Operational Safety...
Page 27: ...27 Block 2 Basic information Qineo NexT...
Page 110: ...110 Job mode...
Page 148: ...148...
Page 149: ...149 Block 4 Additional information...
Page 164: ...164 SD module...
Page 191: ...191 Block 6a Error messages...
Page 207: ...207 Block 6b General maintenance instructions...
Page 212: ...212...
Page 213: ...213 Block 7 Automation...
Page 232: ...232...
Page 233: ...233...
Page 234: ...www qineo de...