4.2.2 Restore the original state of the secondary parameters
1. Press the menu button.
2. Use the left rotary knob to select the menu for the secondary
parameters for the characteristic curve and confirm it by pressing the
knob.
3. Set the correction value to "-0-".
4. To exit the menu, select the exit symbol by turning the rotary knob and
confirm by pressing the knob.
4.2.3 Parameters of operating modes "2-cycle" and "4-cycle"
Gas pre-flow (duration) Correction value (Off, +/- 99)
Inching-in Correction value (+/- 99)
Start time (duration) Correction value (Off, +/- 99)
Start power Correction value (+/- 99)
Upslope Correction value (Off, +/- 99)
Main power Absolute value (m/min)
Downslope Correction value (Off, +/- 99)
End crater (duration) Correction value (Off, +/- 99)
End crater (power) Correction value (+/- 99)
Wire burnback Correction value (+/- 99)
Gas post-flow (duration) Correction value (Off, +/- 99)