6- 19
Sample hold (Trigger mode: One shot)
The held data is updated when the external trigger input is turned ON (at a rising edge).
Note
An indefinite state is held during the following intervals:
From the time immediately after the power is turned ON until the external trigger is turned ON.
From the time the reset input is turned ON until the external trigger is turned ON.
In this type of sample hold, the judgment output is the same as the judgment value.
(However, please note that there are some measurement modes for which this is not the case.)
Operation procedure
■
■
■
(消灯)
(消灯)
HOLD
TRIG
TRIG
TRIG
(消灯)
Lo
Go
Hi
不定
HIGH setting value
LOW setting value
TRIG
TRIG display
HOLD display
Judgment output
(Light OFF)
Indeterminate
2 秒長押し
/
/
選択
キャンセル
選択
キャンセル
確定