6- 6
6-1-2 LOW Setting Value (LO.SET)
Parameter name
Setting value
Remarks
LOW setting value (LO.SET)
Sets a LOW setting value for pass/fail judgment.
−199.9999 to 199.9999 (mm)
[Default: 1.0000]
Operation procedure
Note
Configure settings such that HIGH setting value > LOW setting value.
Although it is possible to set HIGH setting value < LOW setting value, the GO judgment will not be
output.
Related information
The LOW setting value can always be displayed on digital display SUB (green).
For details, refer to "5-2 SUB Display Switching Mode."
HIGH and LOW setting values can be set by teaching using a master work, upper limit work, and
lower limit work.
For details, refer to "5-3 Teaching Mode."
■
■
■
HIGH
GO
LOW
HIGH setting value
LOW setting value
: Included
: Not included
2 秒長押し
/
選択
キャンセル
桁移動
数値変更
確定
S PE E D
O UT PUT
HI. S E T
MAINTE
HY S T E R
T E ACH
T O L <±>
PR. VAL
A D V A N C
A D V A N C
A D V A N C
A D V A N C
CALC
CO PY
BANK
CALIB
PR. O BJ
PR. S AVE
DIRE CT
LE VE R
RE SE T
Long press
for 2 s
Select
Commit
Cancel
Shift between
digits
Change numerical
values