Detailed settings (continued from the preceding page)
Alarm settings (ALARM)
Alarm delay time (DELAY)
Sets the delay time (changeable in 1 ms increments) from
the time the sensor head comes into upthrust position to the
time the alarm activates.
1 to 1,000
[Default: 1,000]
Upthrust check
(PRS.CHK)
Sets the upthrust check ON/OFF.
ON / OFF
[Default: ON]
Upthrust check setting value
(PRS.SET)
Sets the upthrust check setting value when the upthrust
check is set to ON.
−199.9999 to 199.9999 (mm)
[Default: 10.0000]
Catching check
(CAT.CHK)
Sets the catching check ON/OFF.
ON / OFF
[Default: OFF]
Number of connected units check
(PRS.CHK)
If controllers are connected, this performs a check when the
power is turned ON confirming that the number of
connected units has not changed.
ON / OFF
[Default: OFF]
Calculation mode (CALC)
Calculation mode (MODE)
This mode carries out calculations using measurements
from each connected controller, and outputs the judgment
results on the master unit display and from the master unit.
CALC (Calculates) / NOCALC (Does not calculate)
[Default: NOCALC]
Select calculation app (APPLI)
The Select calculation app can be set when calculation
mode is set to CALC.
This selects the application used for the calculation.
MAX (Maximum) / MIN (Minimum) / FLAT (Flatness) /
AVERAG (Average) / STAND (Difference from standard) /
TORSIN (Torsion) / CURVEA (Curvature) / THICK
(Thickness)
[Default: MAX]
Connected unit copy settings (COPY)
Select individual items to be
copied (CPY.SEL)
(Master unit only)
Items to be copied are selected individually.
Select all items to be copied
(CHK.ALL)
(Master unit only)
Selects all items for copying.
YES / NO
[Default: YES]
Execute copy (CPY.EXE)
(Master unit only)
The master unit copies the items selected for copying
(individually selected or all items) to the slave units.
YES / NO
[Default: YES]
Copy lock (LOCK)
(Slave units only)
Prevents copying from the master unit.
ON / OFF
[Default: OFF]
Bank settings (BANK)
Select bank storage (BNK.DAT)
Selects the settings to be read out from those stored in a
bank.
THRS (HIGH setting value, LOW setting value) / THRS.PR
(HIGH setting value, LOW setting value, Preset value) / ALL
(All)
[Default: THRS]