2-48
Cisco MGX 8850 (PXM1E/PXM45), Cisco MGX 8950, Cisco MGX 8830, and Cisco MGX 8880 Configuration Guide
Release 5.0.10, OL-3845-01 Rev. B0, August 16, 2004
Chapter 2 Configuring General Switch Features
Verifying the Hardware Configuration
The dspcd command displays information that is unique to a particular card. For PXM1E cards, the
switch displays a report similar to the following example:
mgx8830b.1.PXM.a>
dspcd 2
mgx8830b System Rev: 03.00 Apr. 25, 2002 22:51:15 GMT
MGX8830 Node Alarm: MAJOR
Slot Number 2 Redundant Slot: 1
Front Card Upper Card Lower Card
---------- ---------- ----------
Inserted Card: PXM1E-4-155 UI Stratum3 SMFIR_4_OC3
Reserved Card: PXM1E-4-155 UI Stratum3 SMFIR_4_OC3
State: Standby Active Active
Serial Number: S1234567890 SAK0325008J SAG05415SW9
Prim SW Rev: 3.0(0.39)A --- ---
Sec SW Rev: 3.0(0.39)A --- ---
Cur SW Rev: 3.0(0.39)A --- ---
Boot FW Rev: 3.0(0.26)A --- ---
800-level Rev: E2 03 4P
800-level Part#: 800-12345-01 800-05787-01 800-18663-01
CLEI Code: /0 0
Reset Reason: On Reset From Shell
Card Alarm: NONE
Failed Reason: None
Miscellaneous Information:
Type <CR> to continue, Q<CR> to stop:
mgx8830b System Rev: 03.00 Apr. 25, 2002 22:51:15 GMT
MGX8830 Node Alarm: MAJOR
Crossbar Slot Status: EMPTY
Alarm Causes
------------
NO ALARMS
mgx8850a.7.PXM.a>
Note
The dspcd and dspcds commands are very similar, but they produce different reports. The dspcd
command displays information about a specific card. The dspcds command displays summary