SPA9000 Field Reference
Voice tab
SPA9000 Voice System Administration Guide
239
B
Daylight Saving Time
Rule (continued)
The <save-time> value is the number of hours, minutes, and/
or seconds to add to the current time during daylight saving
time. The <save-time> value can be preceded by a negative
(-) sign if subtraction is desired instead of addition. The
<save-time> value is in this format: [/[+|-]HH:[mm[:ss]]]
The <month> value equals any value in the range 1-12
(January-December).
The <day> value equals [+|-] any value in the range 1-31.
If <day> is 1, it means the <weekday> on or before the end of
the month (in other words the last occurrence of < weekday>
in that month).
The <weekday> value equals any value in the range 1-7
(Monday-Sunday). It can also equal 0. If the <weekday> value
is 0, this means that the date to start or end daylight saving is
exactly the date given. In that case, the <day> value must not
be negative. If the <weekday> value is not 0 and the <day>
value is positive, then daylight saving starts or ends on the
<weekday> value on or after the date given. If the
<weekday> value is not 0 and the <day> value is negative,
then daylight saving starts or ends on the <weekday> value
on or before the date given.
The abbreviation HH stands for hours (0-23).
The abbreviation mm stands for minutes (0-59).
The abbreviation ss stands for seconds (0-59).
The default Daylight Saving Time Rule is
start=4/1/
7;end=10/-1/7;save=1
.
FXS Port Input Gain
Input gain in dB, up to three decimal places. The range is
6.000 to -12.000.
Default:
-3
.
FXS Port Output Gain
Output gain in dB, up to three decimal places. The range is
6.000 to -12.000. The Call Progress Tones and DTMF
playback level are not affected by the <FXS Port Output
Gain>.
Default:
-3
DTMF Playback Level
Local DTMF playback level in dBm, up to one decimal place.
Default:
-16.0
DTMF Playback Length
Local DTMF playback duration in milliseconds.
Default:
.1
Downloaded from
www.Manualslib.com
manuals search engine