A-13
Catalyst 2900 Series XL and Catalyst 3500 Series XL Software Configuration Guide
78-6511-08
Appendix A System Messages
Error Message and Recovery Procedures
Error Message
FRANK-3-MAINBOARD_INIT_FAILED: Unable to create Mainboard Process\n
Explanation
The creation of the mainboard process for the controller initialization has failed.
Recommended Action
Copy the error message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that might provide information to determine
the nature of the error. If you cannot determine the nature of the error from the error message text or
from the show tech-support output, contact your Cisco technical support representative, and provide
the representative with the gathered information.
Error Message
FRANK-3-MEMORY_INIT_FAILED: \nSlot [dec] Initialization failed:Out of
Memory\n
Explanation
Memory initialization for the controller port instance has failed.
Recommended Action
Copy the error message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that might provide information to determine
the nature of the error. If you cannot determine the nature of the error from the error message text or
from the show tech-support output, contact your Cisco technical support representative, and provide
the representative with the gathered information.
Error Message
FRANK-3-MODULE_CFG_NOT_FOUND: Module configuration not found\n
Explanation
The configuration for the controller module could not be found.
Recommended Action
Copy the error message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that might provide information to determine
the nature of the error. If you cannot determine the nature of the error from the error message text or
from the show tech-support output, contact your Cisco technical support representative, and provide
the representative with the gathered information.
Error Message
FRANK-3-MODULE_INIT_FAILED: Module initialization failed\n
Explanation
The initialization for the controller module failed.
Recommended Action
Copy the error message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that might provide information to determine
the nature of the error. If you cannot determine the nature of the error from the error message text or
from the show tech-support output, contact your Cisco technical support representative, and provide
the representative with the gathered information.
Error Message
FRANK-3-MODULE_INSERT_FAIL: Module in slot [dec] bringup failed
Explanation
The module could not be hot-inserted.
Recommended Action
Copy the error message exactly as it appears on the console or in the system log.
Enter the show tech-support command to gather data that might provide information to determine
the nature of the error. If you cannot determine the nature of the error from the error message text or
from the show tech-support output, contact your Cisco technical support representative, and provide
the representative with the gathered information.