Chapter 2 Installing the Hardware and Software
Installing the Hardware
2-4
Cisco 11000 Series Secure Content Accelerator Configuration Guide
78-13124-06
Prior to installing the Secure Content Accelerator, observe the following
installation requirements:
•
The Maximum Rated Ambient Temperature (Tmra) for the Secure Content
Accelerator is 105° F (40° C). To ensure the Tmra for this device is not
exceeded, allow at least 1 inch (2.54 cm) of space around the four sides of the
Secure Content Accelerator.
•
This equipment is designed to support only its own weight. Do not place other
equipment or material on the Secure Content Accelerator.
Warning
Review nameplate ratings for correct voltage and load
requirements. For safety, this equipment is required to be grounded
through the ground conductor of the AC power cords. Do not
remove the cover of the Secure Content Accelerator. There are
electrical shock hazards present in the unit if the cover is
removed. To reduce the risk of fire or electric shock, do not expose
the Secure Content Accelerator to rain or moisture. To disconnect
power, remove both power cords. Please review the caution label
on the Secure Content Accelerator.
Installing as a Free-Standing Unit
Position the Secure Content Accelerator on a level surface in an area with access
to your network cabling. When installing the Secure Content Accelerator note that
Ethernet and serial cables attach to the front of the chassis and power cables attach
to the back.