Appendix D MiniMax Command Summary
Examples
D-6
Cisco 11000 Series Secure Content Accelerator Configuration Guide
78-13124-06
6.
Copy the firmware image file indicated in Table D-1 to the directory where
Netcat is located.
7.
Using the command console, change the active directory to the one where
Netcat and the image file are located.
8.
Enter the following command, substituting the IP address of the SSL device
and appropriate firmware image filename if necessary.
nc -w 5 10.5.162.105 11768 <css-sca-2fe-k9.phz
9.
On the SSL device’s console, you should see a display similar to the
following:
>>accepted netboot connection from 10.1.6.145:2056
transfer completed 1951970 bytes received
Image address: 0x3a56350
Image length: 951826
Signed: yes
Image type: PHR/PHX file
csid: 0x460313d8
version: 0x00004000
system: 0x00000001
product: 0x00000005
arch: 0x00000007
type: 0x00000006
use zap to save to flash
10.
Enter the following commands to save the image and restart the device.
>>zap
>>boot
11.
Messages are written to the console, indicating necessary files are written.
The device will reboot into the serial console configuration manager.
Installing a Firmware Image (Xmodem)
This example uses the Xmodem to download the image to MiniMax over the
console serial line. The firmware image can be found on the distribution CD
accompanying the device and at the Cisco Web site.
Use the following table to identify the firmware image for use.