SERVICE MANUAL
–
Post eVolve Smart
7 - CHARGE POINT SLAVE DEVICES
CIRCONTROL, S.A.
–
Innovació, 3
–
08232
–
Viladecavalls (Barcelona)
Tel.: +34 937 362 940
–
Fax: +34 937 362 941
23
Web: www.circontrol.com
–
E-mail:
11
Press and hold button
from CEM-C20 for at least 2 seconds
to “9600”
.
12
Press
one time to arrive to “19200”
.
13
Press
two times to arrive to “DONE”
,
wait for “BAUD” to appear
.
14
Press
five times to arrive to “RETURN”
.
15
Press and hold button
from CEM-C20 for at least 2 seconds to
“SETUP”
.
16
Press
two times to arrive to “RETURN”
.
17
Press and hold button
from CEM-C20 for at least 2 seconds.
7.2.2.2
TECHNICAL CHARACTERISTICS
POWER SUPPLY
Voltage
230/127 VAC ±20%
Frequency
50…60Hz
Working temperature
-
25…+70ºC
Relative humidity
5..95%
Maximum consumption
10 VA
SERIAL
Type
RS-485
Baud rate supported
9600, 19200, 38400
LOAD MEASUREMENT
Load Active energy measure accuracy
Class B (EN 50470)
Class 1 (IEC 62053-21)
Load reactive energy measure accuracy
Class 2.0 (IEC 62053-23)
Voltage
3 x 127/220...3 x 230/400 Vc.a.
Frequency
50…60Hz