SERVICE MANUAL
–
Post eVolve Smart
5 - PERIPHERALS OVERVIEW
CIRCONTROL, S.A.
–
Innovació, 3
–
08232
–
Viladecavalls (Barcelona)
Tel.: +34 937 362 940
–
Fax: +34 937 362 941
13
Web: www.circontrol.com
–
E-mail:
5.1
PERIPHERALS CONFIGURATION TABLE
The table below shows all devices with its setup parameters to communicate slave
devices with CCL1-MINI master controller with RS-485 protocol.
-
Setup: Peripheral number.
-
Setup: Baud rate
RS-485 PORT A/1
RS-485 PORT B/2
Device
Meter
(Plug A)
Mode 3
Rail DIN
(Plug A)
LCD
display
RFID
card
reader
Mode 3
Rail DIN
(Plug B)
Meter
(Plug B)
17 A
13 A
26
27
13 B
17 B
Peripheral
number
7
8
9
1
96
8
Baud rate
phase I
19200
19200
phase II
9600
9600
-
It is important to respect the connection position of the devices shown
in the electrical schemes.
-
Do not modify the peripheral number of the devices other than the
one specified in the table above.
-
Do not modify the baud rate of the devices to one that is not specified
in table above. It can cause loss of communication between devices.