SERVICE MANUAL
–
Post eVolve Smart
11 - REPLACEMENT PARTS
CIRCONTROL, S.A.
–
Innovació, 3
–
08232
–
Viladecavalls (Barcelona)
Tel.: +34 937 362 940
–
Fax: +34 937 362 941
72
Web: www.circontrol.com
–
E-mail:
11
REPLACEMENT PARTS
The EV Charge Point offers replacement parts to fix or update the Charge Point. Please,
refer to the post-sales service for more information about the available spare parts at:
12
ERRORS AND TROUBLESHOOTING
12.1
LCD MESSAGE ERRORS
Charge Point errors that affect the whole Charge Point:
DISPLAY MESSAGE
CAUSE
ERRORS VARS CFG
One or more variables from plug configuration
are not configured correctly.
Difference between component configurations
in software and installed components
ERROR DRIVER COM
One or more devices are not communicating
correctly.
ERROR TAMPER
Tamper activated.
Charge Point detects its own door opened.
ERROR RCD
Outlet A or B RCD protection is tripped.
(only in models with RCD trip monitoring)
There are also plug errors, which are related with only one of the plugs, so the other one
may still work:
DISPLAY MESSAGE
CAUSE
PLUG A:
ERROR VARS CFG
One or more variables from plug configuration
are not configured correctly.
Difference between component configurations in
software and installed components
PLUG A:
ERROR DRIVER COM
One or more devices from the plug affected are
not communicating correctly.
PLUG A:
ERROR RCD
Outlet A or B RCD circuit protection is tripped.
(only in models with RCD trip monitoring)
ERROR MCB
Outlet A or B MCB circuit protection is tripped.
(only in models with MCB trip monitoring)
Plug A or Plug B.