6.5.2.11 Command SD (set activation of SHUTDOWN)
The command SD is used to activate the SHUTDOWN input. The shutdown function is not
intended to be used for switching in regular operations. This function is intended for safety
shutdown of the XLC4 and Corona by hardware like a safety cover of the LED module.
Command
Notes
CommandID
SD
SD works in all XLC4 operating modes
Parameter
None
new state
Parameter
Value
Description
new state
“0”
deactivated (default)
“1”
Activated shutdown for all channels
Only for firmware > 5.12:
None
Controller sends a response message
with the current value for
new state
in hex
format.
new state
“0xF”
Deactivated for all channels (default)
corresponding with “SD 0”
“0x0”
Activated shutdown for all channels,
corresponding with “SD 1”
“W”
Writes the state of hex parameters to
permanent memory
Response
sd , space , new state
General notes
Up to firmware 4.26
The new state is applied after next power-up.
From firmware 5.12
The new state for the commands “SD 1” or “SD 0” is applied after next power-up.
The new state for hex parameters (e.g. “SD 0xF”) has to be saved with the command
“SD W” to the permanent memory. Otherwise changes are lost after a power-up cycle.
Example:
SD 1
# activates the shutdown mode
sd 1
SD 0xF
sd 0xf
For a detailed description of the SHUTDOWN function, see section 6.3.