07/2020
Corona II
– LED Line Scan Illumination
PMA_CHR_CD40069_R05_Manual_Corona-II_XLC4
138
7.4.4 Channel configurations
The XLC4 controller checks during the boot process for connected Coronas and displays them
in automatic mode as a single module in the XLC4 commander.
Note:
This selection is stored in the registry and is used at the next start of the
XCL4 commander.
7.4.4.1 Use automatic channel assignment
If this option is selected, the XLC4 commander checks within the XLC4 controller for
connected Corona modules and displays them as a single module in the related tab.
7.4.4.2 Use manual channel assignment
If this option is selected, you can set up an own configuration of the channel to be operated by
the XCL4 commander. So it is e.g. possible to operate four channels of a 680 mm Corona
separately.