For Standard XLC4-1, the MaxCurrentOfType is 1800 mA and MinCurrentOfType is 200 mA.
The chart above shows the behavior of the controller under that condition.
The range of
MaxCurrentOfType
and
MinCurrentOfType
can be further limited by
connected Corona II modules.
If, for example, a Corona II with a maximum current of 1500mA is connected to
channels A and B, and another Corona II with maximum current 1800mA is
connected to C and D, a level of 10V at ACTRL results in a sourcing 1500mA at
channels A and B and 1800mA at channels C and D
Errors are indicated via the status LED and the Signal FAIL.
If the maximum temperature in the temperature sensors is exceeded, the external switch
contact is closed (e.g. to activate a cooling system).