07/2020
Corona II
– LED Line Scan Illumination
PMA_CHR_CD40069_R05_Manual_Corona-II_XLC4
95
6.5.2.7 Command IY (set channel current)
The command IY is used to set and inquire the current of the 4 XLC4 channels.
Command
Notes
CommandID
IY
IY is operative in XLC4 mode
“Command Mode”
and “Bulb Mode”
Parameter
None
channel
current
currentlist
Save state
Read option
Parameter
Value
Description
None
Up to firmware release 4.24:
If no parameter is specified, the command
responds with the saved values for all channels
From firmware release 4.25:
If no parameter is specified, the command
responds with the current values for all channels.
channel
“A”
For channel 1 of the controller
“B”
For channel 2 of the controller
“C”
For channel 3 of the controller
“D”
For channel 4 of the controller
“E”
For Corona II connected to channel 1
“F”
For Corona II connected to channel 2
“G”
For Corona II connected to channel 3
“H”
For Corona II connected to channel 4
current
Integer value
The parameter “
current
” defines the output
current rating in mA. The value is limited to a
range from 200 (mA) to 1800(mA).A connected
Corona module could limit these values to
smaller values. (e.g. 1600 mA)
Currentlist
Save state
“W”
If this flag is set, values are saved to nonvolatile
flash memory as new default current values.
Read option
“S”
From firmware release 4.25:
If this option is used with the IY command, XLC4
responds with the saved values.
Response
iy , space , current , current , current , current
General notes
If the value in
current
is higher than the specified maximum value, an error message is
generated.
An IY command with no channel specified is applied to all 4 channels.