5.3.5 Illuminance
The illuminance/irradiance on the target plane depends on various parameters.
These parameters are:
◼
Reflector type
◼
Operating current
◼
LED temperature
◼
LED type used in module
◼
LED specimen
Reflector
type
LED-
Type
Illuminance
[lx] (min.)
@ 1.8 A
Irradiance
[W/m²] (min.)
@ 1.8 A
y-distance to
Module-Top-
Plane [mm]
Notes
A
04
3.500.000
11.000
y = 60 mm
1,2
B
04
1.200.000
3.800
y = 90 mm
1,2
C
04
550.000
1.750
y = 120 mm
1,2
D
04
390.000
1.200
y = 50 mm
1,2
Reflector
type
LED-
Type
Illuminance
[lx] (min.)
@ 1.5 A
Irradiance
[W/m²] (min.)
@ 1.5 A
y-distance to
Module-Top-
Plane [mm]
Notes
A
01
2.200.000
12.500
y = 60 mm
1,2
B
01
670.000
3.800
y = 90 mm
1,2
C
01
330.000
1.900
y = 120 mm
1,2
D
01
230.000
1.300
y = 50 mm
1,2
Reflector
type
LED-
Type
Illuminance
[lx] (min.)
@ 1.5 A
Irradiance
[W/m²] (min.)
@ 1.5 A
y-distance to
Module-Top-
Plane [mm]
Notes
A
02
2.300.000
4.600
y = 60 mm
1,2
B
02
780.000
1.600
y = 90 mm
1,2
C
02
360.000
730
y = 120 mm
1,2
D
02
250.000
500
y = 50 mm
1,2
Reflector
type
LED-
Type
Illuminance
[lx] (min.)
@ 1.5 A
Irradiance
[W/m²] (min.)
@ 1.5 A
y-distance to
Module-Top-
Plane [mm]
Notes
A
03
500.000
14.800
y = 60 mm
1,2
B
03
165.000
4850
y = 90 mm
1,2
C
03
77.000
2250
y = 120 mm
1,2
D
03
55.000
1600
y = 50 mm
1,2